Enriched with vast industry experience, Starlit Electricals is engaged in manufacturing a wide range of High Voltage Tester. These are designed and developed under international industrial standards.
Specifications
Brand: Starlit Electricals
Detailed Description

High voltage tester of breakdown voltage testers( B D V testers) are useful for measurement of breakdown (flashover) voltage of electrical components, insulation materials instruments, transformers, etc. to ascertain quality of insulation material before planning their usage in electrical applications. For H.V Tester upto 5-10 KV the front panel incorporates all controls for operation of the unit. Easy to use test probes connected to H.T cables can be connected directly voltage to the device under test.

Specifications

Open Circuit Voltage

0to5KVOR0to 10 KVAC. The above voltage can be continuously varied from zero to full value and is continuously monitored by Analog/Digital Panel meter.

Test Current

2 mA to 20 mA OR 3 mA to 100 mA

Accuracy of Reading Power

±2%

Requirements Safety

230 volts AC, ± 10%, 50/60 Hz

 

Protection provided with zero start to prevent accident availability of High

Precautions

Voltage on test terminals. High Voltage on test jig appears only after the variac is set to zero and gradually increased. There is a trip device to trip if the current increases than the required value

Trip settings

The tripping can be reset by a pot which can be varied as peruse requirement

For testers greater than 10 KV upto 100 KV, usually separate transformer and control panels are provided separated by a distance of min 6 meters. The Control panel contains the KV meter, mA meter, MCB’;s and other switches Indicators and protection devices and is connected to transformer by means of a 4 core cable.

Specifications for 30/100KV H.V Tester

Open Circuit Voltage

0 to 30 KV OR 0 to 100 KV AC.

The above voltage can be continuously varied from zero to full value and is continuously monitored by Analog/Digital Panel meter.

Test Current

5 mAto 50 mA OR 10 mAto 100 mA

Accuracy Of Reading

±2%

Power Requirements

230 volts AC, ± 10%, 50/60 Hz

Safety Precautions

Protection provided with zero start to prevent accident availability of High Voltage on test terminals. High Voltage on test jig appears only after the variac is set to zero and gradually increased. There is a trip device to trip if the current increases than the required value

Trip settings

The tripping can be set by a pot which can be varied as per user requirement

 

close

Send Your Message

Email Id
Error message
Subject
Message
Enter between 5 to 3,000 characters, English only.

Enter Image Text *
Your message has been sent successfully.
Your message has been sent successfully. Thanks for register as non member.
Contact Person
( Owner )
Location : Pune
Call : +91 9689323539